Article ID: 000076705 Content Type: Troubleshooting Last Reviewed: 12/20/2022

Why the SmartVID (-V) graded Intel® Stratix® 10 device does not respond to the master power management controller during the Partial Reconfiguration process?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    When using the Intel® Quartus® Prime Pro Edition Software version 18.0, if the SmartVID (-V) graded Intel® Stratix® 10 device is configured in PMBus slave mode, the  Intel® Stratix® 10 device will not respond to any PMBus commands during the Partial Reconfiguration process. If the master power management controller queries the  Intel Stratix 10 device for a voltage update during Partial Reconfiguration, the  Intel Stratix 10 device will not respond.

    Resolution

    After the Partial Reconfiguration process is complete, the  Intel Stratix 10 device will respond to the queries again. The master power management controller needs to re-issue the queries until it gets a response.

     

     

    Related Products

    This article applies to 1 products

    Intel® Stratix® 10 FPGAs and SoC FPGAs