Article ID: 000075106 Content Type: Troubleshooting Last Reviewed: 12/13/2019

Why does the Factory fall back mechanism not work when Direct to Application Mode is used in the Intel® Arria® 10 devices?

Environment

  • Intel® Quartus® Prime Pro Edition
  • Intel® Quartus® Prime Standard Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    When using Remote Update and the Direct to Application (DTA) mode in the Intel® Arria® 10 devices, in order for the Factory fall back mechanism to work, you must enable the ‘Auto-restart configuration after error’  option under the following menu in the Intel Quartus® Prime software: Assignments > Device > Device and Pin Options > General > Auto-restart configuration after error

    Resolution

    This information is scheduled to be added in a future release of the Remote Update Intel® FPGA IP User Guide.

    Related Products

    This article applies to 1 products

    Intel® Arria® 10 FPGAs and SoC FPGAs