Critical Issue
Remote System Upgrade reconfigurations may sometimes fail and requires a power cycle of the Intel® Stratix 10 FPGA to recover the configuration. This problem may be seen at a low probability while reconfiguration is repeated when driving nCONFIG.
This problem applies to either the Active Serial Configuration modes or Avalon® streaming configuration modes.
To work around this problem in the Intel® Quartus® Prime Pro Edition Software v19.2, download and install patch 0.18fw from the following links:
Note: You must install the Intel® Quartus® Prime Pro Edition Software v19.2 before installing this patch.
- Version 19.2 patch 0.18fw for Linux (.run)
- Version 19.2 patch 0.18fw for Window (.exe)
- Readme for the version 19.2 patch 0.18fw (.txt)
This problem will be fixed starting with the Intel® Quartus® Prime Pro Edition Software v20.3.