Article ID: 000074575 Content Type: Troubleshooting Last Reviewed: 01/24/2023

Can the 3.0V I/O banks in Stratix 10 devices support I/O standards of 2.5V, 1.8V, 1.5V or 1.2V?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    When constraining I/O standards of 2.5V, 1.8V, 1.5V, or 1.2V in Stratix® 10 device 3.0V banks, compilation will fail in the Quartus® Prime Pro Edition Software unless the USE_AS_3V_GPIO assignment is applied to these I/O.

    Resolution

    To support I/O standards of 2.5V, 1.8V, 1.5V, or 1.2V in Stratix 10 devices 3.0V banks, the following assignment should be added in the .qsf file along with the IO standard assignment.

    set_instance_assignment -name USE_AS_3V_GPIO ON -to pin_name
     

    Related Products

    This article applies to 1 products

    Intel® Stratix® 10 FPGAs and SoC FPGAs