Article ID: 000073924 Content Type: Troubleshooting Last Reviewed: 08/16/2023

Why does the Intel® Arria® 10 Hard Processor System (HPS) EMAC0 MODE fail to update from RGMII to GMII in .sopcinfo file after regenerating in Platform Designer?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Intel® Quartus® Prime Pro Platform Designer Software version 18.0 and later,  HPS EMAC0 MODE doesn’t update from RGMII to GMII in the <project_name>.sopcinfo file after having changed the EMAC0 mode from RGMII to GMII on Intel® Arria® 10 Hard Processor System and regenerating the design in Platform Designer.

     

    Resolution

    This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software version 19.3. 

    Related Products

    This article applies to 1 products

    Intel® Arria® 10 SX SoC FPGA